Chiswick Business Park is one of London’s flagship office estates, and its buildings answer to the same fire safety duties as any other. Across Buildings 1 and 3, Gemini AMPM remediated the common part fire doors and sealed the service penetrations, from undercroft to roof plant, with four FIRAS certificates behind the work and a programme that has since extended across the park.

The brief

Eighty doors, two dozen
plant rooms, one standard.

The fire doors came first: stairwell doors, riser doorsets, lift motor rooms, plant and comms rooms across six levels of Building 1 and every level of Building 3. Working from the estate’s door condition survey, we priced and delivered the remediation line by line: combination intumescent and smoke seals, intumescent hinge packers, drop down thresholds, ease and adjust, signage, and replacement where a door was past saving. The surveyor’s notes tell you why it mattered: “No BM TRADA peg or certification label seen” is not a sentence any building owner wants on file.

The fire stopping was surveyed by our own team, twelve locations per building: riser cupboards floor by floor, dry risers, tank and switch rooms, gas meter rooms, lift motor rooms. Around two hundred and forty penetration seals went in across the two buildings, fire batt and intumescent mastic applied as fire stopping in accordance with BS 476 Part 20, every location photographed before and after.

What we delivered

The scope,
in full.

Fire door remediation

Roughly eighty common part door leaves across the two buildings: seals, hinge packers, thresholds, adjustment, signage and replacements, delivered from a line by line remedial schedule.

Fire stopping

Around two hundred and forty penetration seals across twenty four locations, fire batt and intumescent mastic to BS 476 Part 20, from basement plant to roof level machinery spaces.

Our own surveys

The fire stopping scope was defined by Gemini’s own December surveys of both buildings, so the remediation was priced against recorded conditions, not assumptions.

Four FIRAS certificates

Fire door maintenance and penetration sealing certificated separately for each building, with photographic QC throughout.

The outcome

Certificated in spring,
retained ever since.

Three of the four workstreams were completed and FIRAS certificated inside March 2024, with the final fire stopping package certificated in early June: four Certificates of Conformity in all, covering fire door maintenance and penetration sealing in both buildings, each backed by before, during and after photography as the quality record.

The clearest verdict is what happened next. The programme extended across the estate, building by building, and the relationship is still live today with fresh fire stopping surveys and phased works continuing through 2026. Passive fire protection is never one visit; it is a discipline a landmark estate has chosen to keep buying from the same team.

Compliance

Delivered
to standard.

  • FIRAS certificated: Certificates of Conformity VC4164, VA4935, PX6844 and OE9818 across fire door maintenance and penetration sealing.
  • BS 476 Part 20: fire stopping systems specified and applied to the tested standard.
  • Tested components: Pyroflex intumescent strips, Astroflame, Eclipse hardware and Nullifire sealing systems, installed to their tested details.